No hot water from a combi boiler is frustrating, but it is not always a breakdown. Several of the most common causes can be checked in a few minutes without tools. This guide takes you through them in order, explains what the symptoms tell you and shows where the safe DIY checks end and an engineer’s job begins.
Key points
- Check the power, the gas supply and the boiler display before anything else.
- Low pressure (below 1 bar) and a frozen condensate pipe are the two faults you can often fix yourself.
- Heating working but no hot water usually points to the diverter valve or flow sensor.
- Never open the boiler casing. Internal faults need a Gas Safe registered engineer.
How a combi boiler makes hot water
A combi boiler heats water on demand, so there is no hot water cylinder in the airing cupboard. When you open a hot tap, a flow sensor detects the water moving and tells the boiler to fire. A diverter valve then sends the heat to a small plate heat exchanger, which warms the mains water on its way to the tap. When the tap closes, the valve swings back to the radiators.
That is why the symptoms matter. If the boiler will not fire at all, you lose both heating and hot water. If the boiler fires for the heating but not for the taps, the problem is usually somewhere in that hot water path.
Checks you can do yourself
- Look at the display. Is there power? Note any fault code or flashing light, as your engineer will want to know it. The manual for your model explains what each code means.
- Check the gas. If you have a gas hob, see if it lights. On a prepayment meter, check there is credit. If nothing gas related works, the issue may be the supply rather than the boiler.
- Check the pressure. Most combis lock out below 1 bar. If the gauge is low, follow our guide to repressurising your boiler.
- Check the hot water settings. Make sure the hot water temperature on the boiler has not been turned right down, and that any hot water or preheat setting is switched on.
- Try more than one tap. If one tap runs cold and the others are hot, the problem is likely that tap or its mixer valve, not the boiler.
- Reset the boiler once. Use the reset button as the manual describes. If it locks out again, stop resetting and book a repair.
Frozen condensate pipe
Modern combis are condensing boilers, and they drain acidic water through a plastic pipe, often running outside to a drain. In a hard frost that water can freeze and block the pipe. The boiler then shuts down and usually shows a fault code. A gurgling sound from the boiler or the pipe is a common clue.
If the pipe runs outside and it has been freezing, you can usually thaw it yourself:
- Find the frozen section. It is usually the lowest point, a bend or the open end near the drain.
- Pour warm water over it from a kettle that has been left to cool for a while, or hold a hot water bottle against it. Do not use boiling water, as it can crack the pipe.
- Reset the boiler once the pipe is clear.
Heating works but no hot water
If your radiators get hot but the taps run cold, the boiler is firing and the gas supply is fine. The fault is in the hot water side, and the usual suspects are:
- Diverter valve. If it sticks in the heating position, hot water never reaches the taps. This is one of the most common combi faults.
- Flow sensor. If it does not detect the water moving, the boiler does not know you want hot water.
- Plate heat exchanger. Limescale can clog it. Much of Hertfordshire has hard water, which makes scale a common cause on older combis. A water softener or scale reducer helps protect a new one.
All three are internal parts and need a boiler repair by a Gas Safe registered engineer. If it is the other way round, with hot water but no heating, see our guide to radiators not heating up.

Lukewarm or on and off hot water
If the hot water arrives but is only warm, or runs hot then cold, check you are not running two hot taps at once. A combi has a set flow rate, and sharing it between a shower and a kitchen tap can drop the temperature. If it happens with a single tap, the likely causes are scale in the heat exchanger, a weak flow sensor or a fault with the burner or fan. These need an engineer to diagnose.
If your home has outgrown a combi, for example a busy household with two bathrooms, a system boiler with a hot water cylinder may suit you better. Our boiler installation team can talk you through the options.
When to call an engineer
Book a repair if the boiler shows a fault code that will not clear, locks out again after a reset, keeps losing pressure, makes banging or whistling noises, leaks, or if you have heating but no hot water. If you have no heating or hot water on a freezing night with children or elderly people in the house, our emergency plumber line is the right call.
Still no hot water?
Our Gas Safe registered engineers repair combi boilers across St Albans and the surrounding Hertfordshire towns. Tell us the fault code and what the boiler is doing, and we will take it from there.
Frequently asked questions
Why does my combi boiler have heating but no hot water?
The most common cause is a diverter valve stuck in the heating position. A faulty flow sensor or a scaled-up plate heat exchanger can do the same. All of these need a Gas Safe registered engineer.
How do I reset my combi boiler?
Most combis have a reset button or a reset setting on the display, and the manual shows the exact steps for your model. Reset once. If the boiler locks out again, there is an underlying fault that needs a repair.
Can low boiler pressure stop hot water?
Yes. Most combis lock out when the pressure falls below about 1 bar, which stops both heating and hot water. Topping up with the filling loop usually gets it going again.
How do I know if my condensate pipe is frozen?
The boiler stops working in freezing weather, often with a fault code, and you may hear gurgling from the boiler or the pipe. The outside section of the pipe may feel solid or show ice at the open end.
Is no hot water an emergency?
Usually it is urgent rather than an emergency. A gas smell is always an emergency: call 0800 111 999. No heating or hot water in freezing weather in a home with vulnerable people should be treated as urgent.